Acid
video
Acid

Acid Potassium Chloride Zinc Electroplating Brightener

Acid potassium chloride zinc electroplating brightener Packing specifications: 25kg/plastic drum 200kg/plastic drum 1000kg/plastic drum on metal pallet Payment: T/T or L/C Delivery Port: Tianjin or Qingdao Test Institution: SGS or CCIC Capacity: 1000 MT per month Period of Validity: 7 days

Description

Process of hydrogen removal:

190-230 ℃

More than 3 hours

Carburizing and tin welding parts temperature 140℃-160℃

Hydrogen removal should be carried out immediately after plating, and the parts should be scrapped after more than 4 hours.

Other steel parts must be dehydrogenated within 4 hours after electroplating.

Spring parts, thin-wall parts (wall thickness less than 0.5mm), high-strength steel parts, must be dehydrogenated.

Copper and copper alloy parts can be free of hydrogen removal.

For parts that cannot be heated too high, a lower temperature (140℃-160℃) can be used to extend the time of hydrogen removal.

 

5

Bath formula and technological parameters

 

 

concentration range

Standard concentration

KCl

200-230 g/L

220g/L

ZnCl

60-100 g/L

60g/L (barrel)

Boric Acid

30-40 g/L

35 g/L

HL-93 Softening Agent

20-30 g/L

25 g/L

HL-93 Brightening Agent

0.6 ml/L- 1.0 ml/L

0.8ml/L

Temperature (℃)

10-55℃

40℃

PH value

4.8-5.6

5.2

DK (A/dm2)

0.1-5

3

 

 

20230722160027-003

Hot Tags: acid potassium chloride zinc electroplating brightener, China acid potassium chloride zinc electroplating brightener manufacturers, suppliers, factory, HL 95 Potassium Chloride Zinc plating Additives B, Zinc Electroplating Alkaline Zincate Cleaning Agent, Acid Electroplating Additives B, Zinc Electroplating Alkaline Zincate Additives, Acid Electroplating Additives A, HL 93 Potassium Chloride Zinc plating Additives A

(0/10)

clearall